15 years ago
|
#usage "<b>Import an EAGLE Netscript into a Schematic</b>\n"
|
||
|
"<p>"
|
||
|
"Opens a file dialog to select a netscript file. "
|
||
|
"Some PCB systems allow to export an EAGLE netscript file in order to make "
|
||
|
"a layout in EAGLE. This ULP allows to use the netscript to generate an "
|
||
|
"EAGLE schematic, too. At least it can be used to draw all net connections "
|
||
|
"in the schematic easily, provided all parts have been placed before. "
|
||
|
"<p>"
|
||
|
"<b>Attention:</b><br>"
|
||
|
"In special situations it could happen that importing a netlist "
|
||
|
"into a schematic (in form of 'airwires' as it happens here) "
|
||
|
"results in misconnections. This is the case if a net line "
|
||
|
"overlaps a pin connection point. If this certain pin under the "
|
||
|
"net should get connected later, EAGLE will connect to the net "
|
||
|
"instead of the pin under it.<p>"
|
||
|
"We want to avoid this problem in the ULP by drawing the net "
|
||
|
"line from the first pin with an offset of 50 mil. This way "
|
||
|
"diagonal net lines will be drawn and there will be hardly pins "
|
||
|
"that lie under net lines.<p>"
|
||
|
"If a net has to be drawn on a further sheet of the schematic "
|
||
|
"EAGLE uses the diagonal offset of 50 mil and places an "
|
||
|
"additional LABEL."
|
||
|
"<p>"
|
||
|
"<author>Author: support@cadsoft.de</author>"
|
||
|
|
||
|
// 2006-01-26 -- modified #usage -- ric
|
||
|
|
||
|
// THIS PROGRAM IS PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED
|
||
|
|
||
|
/* German info
|
||
|
"<b>ACHTUNG</b><p>\n"
|
||
|
"Das Einlesen einer Netzliste (Airwire) in den Schaltplan, "
|
||
|
"kann in besonderen Situationen zu falschen Verbindungen fuehren.<p>\n"
|
||
|
"Werden die Netze als "Luftlinien" zwischen den Bauteilpins gezeichnet, "
|
||
|
"so kann es vorkommen, dass eine Netzlinie Bauteilpins ueberlagert. "
|
||
|
"Wird spaeter <b>dieser</b> Pin unter der Linie an ein Netz angeschlossen "
|
||
|
"so nimmt EAGLE das Netz als Kontaktpunkt und nicht den "
|
||
|
"darunterliegenden Pin.<p>"
|
||
|
"In diesem ULP wird versucht diese Problematik zu umgehen, in dem vom "
|
||
|
"ersten Pin mit einem Offset (50mil) vom Pin weg "
|
||
|
"und dann zum zweiten Pin gezeichnet wird. Dadurch entstehen diagonale "
|
||
|
"Luftlinien die nur in seltenen Faellen einen Pin ueberlagern.<p>\n"
|
||
|
"Wird ein Netz auf einer anderen Schaltplanseite weitergefuehrt, "
|
||
|
"so wird vom Pin um 50 Mil diagonal weggezeichnet und zusaetzlich "
|
||
|
"ein <b>LABEL</b> plaziert.<p>\n"
|
||
|
*/
|
||
|
|
||
|
// Eagle NET-Command definition
|
||
|
string net_name = strupr(argv[1]);
|
||
|
string device_a = strupr(argv[2]);
|
||
|
string pin_a = strupr(argv[3]);
|
||
|
string device_b = strupr(argv[4]);
|
||
|
string pin_b = strupr(argv[5]);
|
||
|
|
||
|
string cmd = "";
|
||
|
|
||
|
string lines[];
|
||
|
int nLines;
|
||
|
string s;
|
||
|
|
||
|
// *** Eagle NET-SCRIPT definition ***
|
||
|
string tok_Signal = "Signal";
|
||
|
string signalLines[];
|
||
|
string signalName;
|
||
|
int signalCnt = 0;
|
||
|
string tok_Change = "Change";
|
||
|
|
||
|
// *** functions ***
|
||
|
|
||
|
int actSheet(UL_SHEET S)
|
||
|
{
|
||
|
return S.number;
|
||
|
}
|
||
|
|
||
|
void readNetList(void)
|
||
|
{
|
||
|
int sn = 0;
|
||
|
do {
|
||
|
if( strstr(lines[sn], tok_Signal) == 0) {
|
||
|
signalCnt = strsplit (signalLines, lines[sn], '\'');
|
||
|
// init NET command
|
||
|
string netName = signalLines[1];
|
||
|
string dev_a = signalLines[3];
|
||
|
string pin_a = signalLines[5];
|
||
|
string dev_b = "";
|
||
|
string pin_b = "";
|
||
|
// start NET command with run-cmd-net.ulp
|
||
|
sn++;
|
||
|
while (strstr(lines[sn], ";") < 0) { // end of Signallist
|
||
|
signalCnt = strsplit (signalLines, lines[sn], '\'');
|
||
|
string dev_b = signalLines[1];
|
||
|
string pin_b = signalLines[3];
|
||
|
cmd += "run " + argv[0] + " '" + netName + "' '" + dev_a + "' '" + pin_a + "' ";
|
||
|
cmd += "'" + dev_b + "' '" + pin_b + "' ;\n";
|
||
|
dev_a = dev_b;
|
||
|
pin_a = pin_b;
|
||
|
sn++;
|
||
|
}
|
||
|
}
|
||
|
if( strstr(lines[sn], tok_Change) == 0) {
|
||
|
sprintf(s, "%s\n", lines[sn]);
|
||
|
cmd += s;
|
||
|
}
|
||
|
sn++;
|
||
|
} while (lines[sn]);
|
||
|
return;
|
||
|
}
|
||
|
|
||
|
// *** MAIN ***
|
||
|
if (schematic) {
|
||
|
|
||
|
// run as net command
|
||
|
if (device_b && pin_b) {
|
||
|
|
||
|
int pinA_sheet = 0;
|
||
|
int pinB_sheet = 0;
|
||
|
int xA, yA, xB, yB;
|
||
|
string g = ";\nGRID LAST;\n";
|
||
|
int actualsheet;
|
||
|
if (sheet) sheet(SH) actualsheet = SH.number;
|
||
|
|
||
|
// *** Schematic coord. ***
|
||
|
schematic(S) {
|
||
|
cmd = "SET WIRE_BEND 2;\nGRID MIL 50 2 ;\n";
|
||
|
S.sheets(SH) {
|
||
|
SH.parts(PA) {
|
||
|
if (PA.name == device_a ) {
|
||
|
PA.instances(IN) {
|
||
|
IN.gate.symbol.pins(P) { // Pin
|
||
|
if (P.contact) {
|
||
|
string cp = P.contact.name; // PAD name von Connect/Pad
|
||
|
if (cp == pin_a) {
|
||
|
xA = P.x;
|
||
|
yA = P.y;
|
||
|
pinA_sheet = SH.number;
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
if (device_b) {
|
||
|
if (PA.name == device_b ) {
|
||
|
PA.instances(IN) {
|
||
|
IN.gate.symbol.pins(P) { // Pin
|
||
|
if (P.contact) {
|
||
|
string cp = P.contact.name; // PAD name von Connect/Pad
|
||
|
if (cp == pin_b) {
|
||
|
xB = P.x;
|
||
|
yB = P.y;
|
||
|
pinB_sheet = SH.number;
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
}
|
||
|
if (net_name) net_name = "'" + net_name + "'";
|
||
|
// place Name in ' ' for NET-Command
|
||
|
|
||
|
string s;
|
||
|
if ( (pinA_sheet != 0) && (pinB_sheet != 0) ) {
|
||
|
if (pinA_sheet == pinB_sheet) {
|
||
|
if (actualsheet != pinA_sheet) {
|
||
|
sprintf(s, "EDIT .s%d;\n", pinA_sheet);
|
||
|
cmd += s;
|
||
|
}
|
||
|
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xA), u2mil(yA) );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f)", u2mil(xA)+50, u2mil(yA)-50 );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f);\n", u2mil(xB), u2mil(yB) );
|
||
|
cmd += s;
|
||
|
exit (cmd + g);
|
||
|
}
|
||
|
else {
|
||
|
if (actualsheet != pinA_sheet) {
|
||
|
sprintf(s, "EDIT .s%d;\n", pinA_sheet);
|
||
|
cmd += s;
|
||
|
}
|
||
|
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xA), u2mil(yA) );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
|
||
|
cmd += s;
|
||
|
sprintf(s, "LABEL (%.3f %.3f)", u2mil(xA), u2mil(yA) );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
|
||
|
cmd += s;
|
||
|
sprintf(s, "CHANGE LAYER 91 (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
|
||
|
cmd += s;
|
||
|
|
||
|
if (actualsheet != pinB_sheet) {
|
||
|
sprintf(s, "EDIT .s%d;\n", pinB_sheet);
|
||
|
cmd += s;
|
||
|
}
|
||
|
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xB), u2mil(yB) );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
|
||
|
cmd += s;
|
||
|
sprintf(s, "LABEL (%.3f %.3f)", u2mil(xB), u2mil(yB) );
|
||
|
cmd += s;
|
||
|
sprintf(s, " (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
|
||
|
cmd += s;
|
||
|
sprintf(s, "CHANGE LAYER 91 (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
|
||
|
cmd += s;
|
||
|
exit (cmd + g);
|
||
|
}
|
||
|
}
|
||
|
else {
|
||
|
cmd = "";
|
||
|
if (pinA_sheet == 0) cmd += "Device " + device_a + " Pin " + pin_a + "\n";
|
||
|
if (pinB_sheet == 0) cmd += "Device " + device_b + " Pin " + pin_b + "\n";
|
||
|
cmd += "not fond!";
|
||
|
dlgMessageBox(cmd, "OK");
|
||
|
exit (-1);
|
||
|
}
|
||
|
}
|
||
|
|
||
|
// run as script converter
|
||
|
else {
|
||
|
string ulp_path ;
|
||
|
char bkslash = '/';
|
||
|
int pos = strrchr(argv[0], bkslash);
|
||
|
if (pos >= 0) {
|
||
|
ulp_path = strsub(argv[0], 0, pos + 1);
|
||
|
}
|
||
|
|
||
|
// File handling
|
||
|
int n = 0;
|
||
|
string text;
|
||
|
string NetListfileName;
|
||
|
int nBytes;
|
||
|
|
||
|
if (argv[1]) {
|
||
|
NetListfileName = argv[1];
|
||
|
}
|
||
|
else {
|
||
|
NetListfileName = dlgFileOpen("Select Script File", "*.scr", "*.*");
|
||
|
}
|
||
|
|
||
|
if (NetListfileName) {
|
||
|
nLines = fileread(lines, NetListfileName);
|
||
|
readNetList();
|
||
|
}
|
||
|
output(NetListfileName + "x", "wt") printf("%s", cmd);
|
||
|
|
||
|
exit (cmd);
|
||
|
}
|
||
|
}
|
||
|
else {
|
||
|
dlgMessageBox("Start this ULP from a schematic!", "OK");
|
||
|
exit (0);
|
||
|
}
|