neingeist
/
arduinisten
Archived
1
0
Fork 0
You cannot select more than 25 topics Topics must start with a letter or number, can include dashes ('-') and can be up to 35 characters long.
This repo is archived. You can view files and clone it, but cannot push or open issues/pull-requests.

307 lines
9.3 KiB
Plaintext

#usage "<nobr><b>Import an EAGLE-Net-List into a schematic</b>\n"
"<p>"
"Usage:<br>"
"RUN cmd-net-list2sch [<i>netlist-file</i> ] <br>"
"RUN cmd-net-list2sch [<i>net part pin part pin</i> ] <br>"
"RUN cmd-net-list2sch : Opens a file dialog to select the Net list file."
"<p>"
"Example:<br>"
"RUN cmd-net-list2sch hexapod.lst<br>"
"RUN cmd-net-list2sch IN1 R1 1 C1 2<br>"
"RUN cmd-net-list2sch clk ic1 9 ic3 15<br>"
"<p>"
"<b>Attention:</b>"
"In special situations it could happen that importing a netlist into a schematic "
"(in form of 'airwires' as it happens here) results in misconnections.<br>"
"This is the case if a net line overlaps a pin connection point.<br>"
"If this certain pin under the net should get connected later, EAGLE will connect to the net "
"instead of the pin under it.<br>"
"We want to avoid this problem in the ULP by drawing the net "
"line from the first pin with an offset of 50 mil. This way "
"diagonal net lines will be drawn <br>"
"and there will be hardly pins that lie under net lines.<br>"
"If a net has to be drawn on a further sheet of the schematic "
"EAGLE uses the diagonal offset of 50 mil and places an "
"additional LABEL."
"<p></nobr>"
"<author>Author: support@cadsoft.de</author>"
// THIS PROGRAM IS PROVIDED AS IS AND WITHOUT WARRANTY OF ANY KIND, EXPRESSED OR IMPLIED
string Hilfe = "<p><b>ACHTUNG:</b><br>\n"
"Das Einlesen einer Netzliste (Airwire) in den Schaltplan, " +
"kann in besonderen Situationen zu falschen Verbindungen f&uuml;hren.<br>" +
"Werden die Netze als <i>Luftlinien</i> zwischen den Bauteilpins gezeichnet, " +
"so kann es vorkommen, dass eine Netzlinie Bauteilpins &uuml;berlagert.<br>" +
"Wird sp&auml;ter <b>dieser</b> Pin unter der Linie an ein Netz angeschlossen " +
"so nimmt EAGLE das Netz als Kontaktpunkt und nicht den darunterliegenden Pin.<br>" +
"In diesem ULP wird versucht diese Problematik zu umgehen, in dem vom " +
"ersten Pin mit einem Offset (50mil) diagonal vom Pin weg, " +
"und dann direkt zum zweiten Pin gezeichnet wird.<br>" +
"Dadurch entstehen diagonale Luftlinien die nur in seltenen F&auml;llen einen Pin " +
"&uuml;berlagern.<br>" +
"Wird ein Netz auf einer anderen Schaltplanseite weitergef&uuml;hrt, " +
"so wird vom Pin um 50 Mil diagonal weggezeichnet und zus&auml;tzlich " +
"ein <b>LABEL</b> plaziert.</nobr>";
if (argc < 2) dlgMessageBox(usage + Hilfe, "OK");
string Version = "1.0.1"; // 2009-12-15 command RUN path/filename option with apostroph while space in path/filename
// check first if part place bevor run script. alf@cadsoft.de
// Eagle NET-Command definition
string net_name = strupr(argv[1]);
string part_a = strupr(argv[2]);
string pin_a = strupr(argv[3]);
string part_b = strupr(argv[4]);
string pin_b = strupr(argv[5]);
string cmd = "";
string lines[];
int nLines;
//string s;
// *** Eagle NET LIST definition ***
string tok_Net = "Net";
string tok_Part = "Part";
string tok_Pad = "Pad";
string netlistLines[];
string signalName;
int signalCnt = 0;
string NetListfileName;
int cntP = 0;
string Parts[];
// *** functions ***
int actSheet(UL_SHEET S) {
return S.number;
}
int partplaced(string partname) { // 2009-12-15
for (int n = 0; n < cntP; n++) {
if (Parts[n] == partname) return 1;
}
return 0;
}
void readNetList(void) {
int sn = 0;
for (sn = 0; sn < nLines; sn++) { // search for start line "Net Part Pin" in Eagle Netlist
if( (strstr(lines[sn], tok_Net) == 0) && (strstr(lines[sn], tok_Part) >= 8) && (strstr(lines[sn], tok_Pad) >= 16) ) {
sn++;
break;
}
}
if (sn == nLines) {
dlgMessageBox(NetListfileName + " is not a Eagle-Netlist", "OK");
exit (0);
}
string netName;
string par;
string pin;
string par_b;
string pin_b;
do {
signalCnt = strsplit (netlistLines, lines[sn], ' ');
if (signalCnt > 1) {
// init NET command
int ncnt = 1;
if (netlistLines[0]) {
netName = netlistLines[0];
do {
if (netlistLines[ncnt]) {
par = netlistLines[ncnt];
ncnt++;
break;
}
ncnt++;
} while (ncnt <= signalCnt);
do {
if (netlistLines[ncnt] ) {
pin = netlistLines[ncnt];
ncnt++;
}
ncnt++;
} while (ncnt <= signalCnt);
}
else {
do {
if (netlistLines[ncnt]) {
par_b = netlistLines[ncnt];
ncnt++;
break;
}
ncnt++;
} while (ncnt <= signalCnt);
do {
if (netlistLines[ncnt] ) {
pin_b = netlistLines[ncnt];
}
ncnt++;
} while (ncnt <= signalCnt);
if (partplaced(par)) { // 2009-12-15 alf@cadsoft.de
cmd += "RUN '" + argv[0] + "' " + netName + " " + par + " " + pin + " ";
cmd += par_b + " " + pin_b + ";\n";
par = par_b;
pin = pin_b;
par_b = "";
pin_b = "";
}
else {
dlgMessageBox("! Part "+ par +" not foud.","OK");
exit(-2);
}
}
}
sn++;
} while (sn <= nLines);
return;
}
// *** MAIN ***
if (schematic) {
// run as net command
if (part_b && pin_b) {
int pinA_sheet = 0;
int pinB_sheet = 0;
int xA, yA, xB, yB;
string g = ";\nGRID LAST;\n";
int actualsheet;
if (sheet) sheet(SH) actualsheet = SH.number;
// *** Schematic coord. ***
schematic(S) {
cmd = "SET WIRE_BEND 2;\nGRID MIL 50 2 ;\n";
S.sheets(SH) {
SH.parts(PA) {
if (PA.name == part_a ) {
PA.instances(IN) {
IN.gate.symbol.pins(P) { // Pin
if (P.contact) {
string cp = P.contact.name; // PAD name von Connect/Pad
if (cp == pin_a) {
xA = P.x;
yA = P.y;
pinA_sheet = SH.number;
}
}
}
}
}
if (part_b) {
if (PA.name == part_b ) {
PA.instances(IN) {
IN.gate.symbol.pins(P) { // Pin
if (P.contact) {
string cp = P.contact.name; // PAD name von Connect/Pad
if (cp == pin_b) {
xB = P.x;
yB = P.y;
pinB_sheet = SH.number;
}
}
}
}
}
}
}
}
}
if (net_name) net_name = "'" + net_name + "'"; // place Name in ' ' for NET-Command
string s;
if ( (pinA_sheet != 0) && (pinB_sheet != 0) ) {
if (pinA_sheet == pinB_sheet) {
if (actualsheet != pinA_sheet) {
sprintf(s, "EDIT .s%d;\n", pinA_sheet);
cmd += s;
}
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xA), u2mil(yA) );
cmd += s;
sprintf(s, " (%.3f %.3f)", u2mil(xA)+50, u2mil(yA)-50 );
cmd += s;
sprintf(s, " (%.3f %.3f);\n", u2mil(xB), u2mil(yB) );
cmd += s;
exit (cmd + g);
}
else {
if (actualsheet != pinA_sheet) {
sprintf(s, "EDIT .s%d;\n", pinA_sheet);
cmd += s;
}
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xA), u2mil(yA) );
cmd += s;
sprintf(s, " (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
cmd += s;
sprintf(s, "LABEL (%.3f %.3f)", u2mil(xA), u2mil(yA) );
cmd += s;
sprintf(s, " (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
cmd += s;
sprintf(s, "CHANGE LAYER 91 (%.3f %.3f);\n", u2mil(xA)+50, u2mil(yA)+50 );
cmd += s;
if (actualsheet != pinB_sheet) {
sprintf(s, "EDIT .s%d;\n", pinB_sheet);
cmd += s;
}
sprintf(s, "NET %s (%.3f %.3f)", net_name, u2mil(xB), u2mil(yB) );
cmd += s;
sprintf(s, " (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
cmd += s;
sprintf(s, "LABEL (%.3f %.3f)", u2mil(xB), u2mil(yB) );
cmd += s;
sprintf(s, " (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
cmd += s;
sprintf(s, "CHANGE LAYER 91 (%.3f %.3f);\n", u2mil(xB)+50, u2mil(yB)+50 );
cmd += s;
exit (cmd + g);
}
}
else {
cmd = "";
if (pinA_sheet == 0) cmd += "part " + part_a + " Pin " + pin_a + "\n";
if (pinB_sheet == 0) cmd += "part " + part_b + " Pin " + pin_b + "\n";
cmd += "not fond!";
dlgMessageBox(cmd, "OK");
exit (-1);
}
}
// run as script converter
else {
schematic(S) {
S.parts(P) {
Parts[cntP] = P.name;
cntP++;
}
}
int n = 0;
string text;
int nBytes;
if (argv[1]) NetListfileName = argv[1];
else NetListfileName = dlgFileOpen("Select Script File", "*.*", "*.*");
if (NetListfileName) {
nLines = fileread(lines, NetListfileName);
readNetList();
}
output(NetListfileName + "x", "wtD") printf("%s", cmd); // D == temporary file
exit (cmd);
}
}
else {
dlgMessageBox("Start this ULP from a schematic!", "OK");
exit (0);
}